jevylux: Operating system name and version: SLES 11 Version of smsd: 3.1.14 Smsd installed from: sources / package repository / from elsewhere... Name and model of a modem / phone: Siemens TC35 Interface: serial / USB / some adapter...serial Hi, I use a Siemens TC35 modem, and the modem blocks from time to time. In the logs, I see the following line : 2012-06-11 10:16:44,7, GSM1: Command is sent, waiting for the answer 2012-06-11 10:17:51,7, GSM1: put_command expected (OK)|(ERROR), timeout occurred. 1. 2012-06-11 10:17:51,7, GSM1: <- †€`xf.f..f˜..`xæx`....˜†€þ 2012-06-11 10:17:51,3, GSM1: The modem answer was not OK: †€`xfff˜`xæx`˜†€þ After power down/power up of the modem, eveything works again, for a time. The smsd config file contains : [GSM1] device = /dev/ttyS0 incoming = yes pin = xxxx report = yes init = ATE0+CPMS="ME" init2 = ATE0+CNMI=2,0,0,2,1 I allready replaced the modem, the new one (same model) has the same problem. Has anybody else the same problems ? Is there another modem i should use ? (Falcom doen't produce them anymore. Thanks in advance for any help.