juliowilly: Thanks for fast reply.
Here is the log ( I purge it from
AT+CSQ
2017-01-05 14:26:11,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:11,7, GSM1: <- +CSQ: 13,99 OK
)
Too long...
2017-01-05 14:26:08,6, GSM1: Checking device for incoming SMS
2017-01-05 14:26:08,6, GSM1: Checking if modem is ready
2017-01-05 14:26:09,7, GSM1: -> AT
2017-01-05 14:26:09,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:09,7, GSM1: <- OK
2017-01-05 14:26:09,6, GSM1: Pre-initializing modem
2017-01-05 14:26:09,7, GSM1: -> ATE0+CMEE=1;+CREG=2
2017-01-05 14:26:09,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:10,7, GSM1: <- OK
2017-01-05 14:26:10,6, GSM1: Initializing modem
2017-01-05 14:26:10,7, GSM1: -> AT+CPMS="SM","ME","SR"
2017-01-05 14:26:10,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:10,7, GSM1: <- +CPMS: 1,30,0,0,0,1 OK
2017-01-05 14:26:10,7, GSM1: -> AT^SYSCFG=13,1,3FFFFFFF,2,4
2017-01-05 14:26:10,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:11,7, GSM1: <- OK
2017-01-05 14:26:11,7, GSM1: -> AT+CSQ
2017-01-05 14:26:11,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:11,7, GSM1: <- +CSQ: 13,99 OK
2017-01-05 14:26:11,6, GSM1: Signal Strength Indicator: (13,99) -87 dBm (Workable), Bit Error Rate: not known or not detectable
2017-01-05 14:26:11,6, GSM1: Checking if Modem is registered to the network
2017-01-05 14:26:11,7, GSM1: -> AT+CREG?
2017-01-05 14:26:11,7, GSM1: Command is sent, waiting for the answer
2017-01-05 14:26:22,7, GSM1: put_command expected (\+CREG:.*OK)|(ERROR), timeout occurred. 1.
2017-01-05 14:26:22,7, GSM1: <- COMMAND NOT SUPPORT
2017-01-05 14:26:22,3, GSM1: Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying
2017-01-05 14:26:22,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 14:26:22 3 GSM1 "Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying"
2017-01-05 14:26:22,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0)2017-01-05 15:09:34,2, smsd: Smsd mainprocess is awaiting the termination of all modem handlers. PID: 2812.
2017-01-05 15:09:34,2, GSM1: Modem handler 0 terminated. PID: 2813, was started 17-01-05 14:06:03.
2017-01-05 15:09:34,2, smsd: Smsd mainprocess terminated. PID 2812, was started 17-01-05 14:06:03.
2017-01-05 15:09:35,2, smsd: Smsd v3.1.15 started.
2017-01-05 15:09:35,2, smsd: Running as root:root.
2017-01-05 15:09:36,7, smsd: Running startup_check (shell): /www/spool/sms/incoming/smsd_script.JylN1c /tmp/smsd_data.POr7Av
2017-01-05 15:09:36,7, smsd: Done: startup_check (shell), execution time 0 sec., status: 0 (0)
2017-01-05 15:09:36,4, smsd: File mode creation mask: 022 (0644, rw-r--r--).
2017-01-05 15:09:36,5, smsd: Outgoing file checker has started. PID: 30793.
2017-01-05 15:09:36,7, smsd: All PID's: 30793,30794
2017-01-05 15:09:36,5, GSM1: Modem handler 0 has started. PID: 30794.
2017-01-05 15:09:36,5, GSM1: Using check_memory_method 1: CPMS is used.
2017-01-05 15:09:36,6, GSM1: I have to send 1 short message for /www/spool/sms/checked/simplesms_0160715
2017-01-05 15:09:36,6, GSM1: Sending SMS from to 22890392920
2017-01-05 15:09:36,6, GSM1: Checking if modem is ready
2017-01-05 15:09:36,7, GSM1: -> AT
2017-01-05 15:09:36,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:36,7, GSM1: <- OK
2017-01-05 15:09:36,6, GSM1: Pre-initializing modem
2017-01-05 15:09:36,7, GSM1: -> ATE0+CMEE=1;+CREG=2
2017-01-05 15:09:36,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:37,7, GSM1: <- OK
2017-01-05 15:09:37,6, GSM1: Checking if modem needs PIN
2017-01-05 15:09:37,7, GSM1: -> AT+CPIN?
2017-01-05 15:09:37,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:37,7, GSM1: <- +CPIN: READY OK
2017-01-05 15:09:37,6, GSM1: Initializing modem
2017-01-05 15:09:37,7, GSM1: -> AT+CPMS="SM","ME","SR"
2017-01-05 15:09:37,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:38,7, GSM1: <- +CPMS: 4,30,0,0,0,1 OK
2017-01-05 15:09:38,7, GSM1: -> AT^SYSCFG=13,1,3FFFFFFF,2,4
2017-01-05 15:09:38,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:38,7, GSM1: <- OK
2017-01-05 15:09:38,7, GSM1: -> AT+CSQ
2017-01-05 15:09:38,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:39,7, GSM1: <- +CSQ: 12,99 OK
2017-01-05 15:09:39,6, GSM1: Signal Strength Indicator: (12,99) -89 dBm (Workable), Bit Error Rate: not known or not detectable
2017-01-05 15:09:39,6, GSM1: Checking if Modem is registered to the network
2017-01-05 15:09:39,7, GSM1: -> AT+CREG?
2017-01-05 15:09:39,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:39,7, GSM1: <- +CREG: 2,1, B, 2B06 OK
2017-01-05 15:09:39,6, GSM1: Modem is registered to the network
2017-01-05 15:09:39,6, GSM1: Location area code: B, Cell ID: 2B06
2017-01-05 15:09:39,7, GSM1: -> AT+CSQ
2017-01-05 15:09:39,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:40,7, GSM1: <- +CSQ: 12,99 OK
2017-01-05 15:09:40,6, GSM1: Signal Strength Indicator: (12,99) -89 dBm (Workable), Bit Error Rate: not known or not detectable
2017-01-05 15:09:40,6, GSM1: Selecting PDU mode
2017-01-05 15:09:40,7, GSM1: -> AT+CMGF=0
2017-01-05 15:09:40,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:40,7, GSM1: <- OK
2017-01-05 15:09:40,7, GSM1: -> AT+CIMI
2017-01-05 15:09:40,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:41,7, GSM1: <- 615010103851049 OK
2017-01-05 15:09:41,7, GSM1: -> AT+CGSN
2017-01-05 15:09:41,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:41,7, GSM1: <- 359740021706302 OK
2017-01-05 15:09:41,5, GSM1: CGSN: 359740021706302
2017-01-05 15:09:41,5, GSM1: IMSI: 615010103851049
2017-01-05 15:09:41,6, GSM1: Checking if reading of messages is supported
2017-01-05 15:09:41,7, GSM1: -> AT+CPMS?
2017-01-05 15:09:41,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:42,7, GSM1: <- +CPMS: "SM",4,30,"ME",0,0,"SR",0,1 OK
2017-01-05 15:09:42,7, GSM1: -> AT+CMGS=26
2017-01-05 15:09:42,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:42,7, GSM1: <- >
2017-01-05 15:09:42,7, GSM1: -> 0031000B912298302929F00000FF0DD4F29C0E72D7DB65F91B9403.
2017-01-05 15:09:42,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:45,7, GSM1: <- +CMS ERROR: 500 (Unknown error)
2017-01-05 15:09:45,3, GSM1: The modem answer was not OK: +CMS ERROR: 500 (Unknown error)
2017-01-05 15:09:45,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:09:45 3 GSM1 "The modem answer was not OK: +CMS ERROR: 500 (Unknown error)"
2017-01-05 15:09:45,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0)
2017-01-05 15:09:45,3, GSM1: Exec: alarmhandler encountered errors:
2017-01-05 15:09:45,3, GSM1: ! sh: you need to specify whom to kill
2017-01-05 15:09:45,5, GSM1: Waiting 10 sec. before retrying
2017-01-05 15:09:55,6, GSM1: Checking if modem is ready
2017-01-05 15:09:55,7, GSM1: -> AT
2017-01-05 15:09:55,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:09:56,7, GSM1: <- OK
2017-01-05 15:09:59,7, GSM1: -> 0031000B912298302929F00000FF0DD4F29C0E72D7DB65F91B9403.
2017-01-05 15:09:59,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:10:02,7, GSM1: <- +CMS ERROR: 500 (Unknown error)
2017-01-05 15:10:02,3, GSM1: The modem answer was not OK: +CMS ERROR: 500 (Unknown error)
2017-01-05 15:10:02,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:10:02 3 GSM1 "The modem answer was not OK: +CMS ERROR: 500 (Unknown error)"
2017-01-05 15:10:02,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0)
2017-01-05 15:10:26,7, GSM1: -> 0031000B912298302929F00000FF0DD4F29C0E72D7DB65F91B9403.
2017-01-05 15:10:26,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:10:29,7, GSM1: <- +CMS ERROR: 500 (Unknown error)
2017-01-05 15:10:29,3, GSM1: The modem answer was not OK: +CMS ERROR: 500 (Unknown error)
2017-01-05 15:10:29,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:10:29 3 GSM1 "The modem answer was not OK: +CMS ERROR: 500 (Unknown error)"2017-01-05 15:12:18,7, GSM1: <- OK
2017-01-05 15:18:08,6, GSM1: Checking if Modem is registered to the network
2017-01-05 15:18:08,7, GSM1: -> AT+CREG?
2017-01-05 15:18:08,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:18:18,7, GSM1: put_command expected (\+CREG:.*OK)|(ERROR), timeout occurred. 3.
2017-01-05 15:18:18,7, GSM1: <-
2017-01-05 15:18:18,3, GSM1: Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying
2017-01-05 15:18:18,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:18:18 3 GSM1 "Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying"
2017-01-05 15:18:18,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0)
2017-01-05 15:18:18,3, GSM1: Exec: alarmhandler encountered errors:
2017-01-05 15:18:18,3, GSM1: ! sh: you need to specify whom to kill
2017-01-05 15:18:19,7, GSM1: -> AT+CSQ
2017-01-05 15:18:19,7, GSM1: Command is sent, waiting for the answer
2017-01-05 15:18:30,7, GSM1: put_command expected (OK)|(ERROR), timeout occurred. 4.
2017-01-05 15:18:30,7, GSM1: <-
2017-01-05 15:18:30,7, GSM1: -> AT+CREG?
|