juliowilly: Hi sir! I let the server reun for a few days and <b>check_network = no</> seems work. Thank a lot for your availability. You are awesome! ;)
juliowilly: I noticed than when i set init = AT+CPMS="SM","SM","SM" the modem can't receive incoming sms and report. I know it's strange but i try many combination and only this one init = AT+CPMS="SM","ME","SR" seems work and stay stable. For check_network = no, i try it and let you know. Thanks again
juliowilly: Thanks for fast reply. Here is the log ( I purge it from AT+CSQ 2017-01-05 14:26:11,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:11,7, GSM1: <- +CSQ: 13,99 OK ) Too long... 2017-01-05 14:26:08,6, GSM1: Checking device for incoming SMS 2017-01-05 14:26:08,6, GSM1: Checking if modem is ready 2017-01-05 14:26:09,7, GSM1: -> AT 2017-01-05 14:26:09,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:09,7, GSM1: <- OK 2017-01-05 14:26:09,6, GSM1: Pre-initializing modem 2017-01-05 14:26:09,7, GSM1: -> ATE0+CMEE=1;+CREG=2 2017-01-05 14:26:09,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:10,7, GSM1: <- OK 2017-01-05 14:26:10,6, GSM1: Initializing modem 2017-01-05 14:26:10,7, GSM1: -> AT+CPMS="SM","ME","SR" 2017-01-05 14:26:10,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:10,7, GSM1: <- +CPMS: 1,30,0,0,0,1 OK 2017-01-05 14:26:10,7, GSM1: -> AT^SYSCFG=13,1,3FFFFFFF,2,4 2017-01-05 14:26:10,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:11,7, GSM1: <- OK 2017-01-05 14:26:11,7, GSM1: -> AT+CSQ 2017-01-05 14:26:11,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:11,7, GSM1: <- +CSQ: 13,99 OK 2017-01-05 14:26:11,6, GSM1: Signal Strength Indicator: (13,99) -87 dBm (Workable), Bit Error Rate: not known or not detectable 2017-01-05 14:26:11,6, GSM1: Checking if Modem is registered to the network 2017-01-05 14:26:11,7, GSM1: -> AT+CREG? 2017-01-05 14:26:11,7, GSM1: Command is sent, waiting for the answer 2017-01-05 14:26:22,7, GSM1: put_command expected (\+CREG:.*OK)|(ERROR), timeout occurred. 1. 2017-01-05 14:26:22,7, GSM1: <- COMMAND NOT SUPPORT 2017-01-05 14:26:22,3, GSM1: Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying 2017-01-05 14:26:22,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 14:26:22 3 GSM1 "Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying" 2017-01-05 14:26:22,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0)2017-01-05 15:09:34,2, smsd: Smsd mainprocess is awaiting the termination of all modem handlers. PID: 2812. 2017-01-05 15:09:34,2, GSM1: Modem handler 0 terminated. PID: 2813, was started 17-01-05 14:06:03. 2017-01-05 15:09:34,2, smsd: Smsd mainprocess terminated. PID 2812, was started 17-01-05 14:06:03. 2017-01-05 15:09:35,2, smsd: Smsd v3.1.15 started. 2017-01-05 15:09:35,2, smsd: Running as root:root. 2017-01-05 15:09:36,7, smsd: Running startup_check (shell): /www/spool/sms/incoming/smsd_script.JylN1c /tmp/smsd_data.POr7Av 2017-01-05 15:09:36,7, smsd: Done: startup_check (shell), execution time 0 sec., status: 0 (0) 2017-01-05 15:09:36,4, smsd: File mode creation mask: 022 (0644, rw-r--r--). 2017-01-05 15:09:36,5, smsd: Outgoing file checker has started. PID: 30793. 2017-01-05 15:09:36,7, smsd: All PID's: 30793,30794 2017-01-05 15:09:36,5, GSM1: Modem handler 0 has started. PID: 30794. 2017-01-05 15:09:36,5, GSM1: Using check_memory_method 1: CPMS is used. 2017-01-05 15:09:36,6, GSM1: I have to send 1 short message for /www/spool/sms/checked/simplesms_0160715 2017-01-05 15:09:36,6, GSM1: Sending SMS from to 22890392920 2017-01-05 15:09:36,6, GSM1: Checking if modem is ready 2017-01-05 15:09:36,7, GSM1: -> AT 2017-01-05 15:09:36,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:36,7, GSM1: <- OK 2017-01-05 15:09:36,6, GSM1: Pre-initializing modem 2017-01-05 15:09:36,7, GSM1: -> ATE0+CMEE=1;+CREG=2 2017-01-05 15:09:36,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:37,7, GSM1: <- OK 2017-01-05 15:09:37,6, GSM1: Checking if modem needs PIN 2017-01-05 15:09:37,7, GSM1: -> AT+CPIN? 2017-01-05 15:09:37,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:37,7, GSM1: <- +CPIN: READY OK 2017-01-05 15:09:37,6, GSM1: Initializing modem 2017-01-05 15:09:37,7, GSM1: -> AT+CPMS="SM","ME","SR" 2017-01-05 15:09:37,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:38,7, GSM1: <- +CPMS: 4,30,0,0,0,1 OK 2017-01-05 15:09:38,7, GSM1: -> AT^SYSCFG=13,1,3FFFFFFF,2,4 2017-01-05 15:09:38,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:38,7, GSM1: <- OK 2017-01-05 15:09:38,7, GSM1: -> AT+CSQ 2017-01-05 15:09:38,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:39,7, GSM1: <- +CSQ: 12,99 OK 2017-01-05 15:09:39,6, GSM1: Signal Strength Indicator: (12,99) -89 dBm (Workable), Bit Error Rate: not known or not detectable 2017-01-05 15:09:39,6, GSM1: Checking if Modem is registered to the network 2017-01-05 15:09:39,7, GSM1: -> AT+CREG? 2017-01-05 15:09:39,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:39,7, GSM1: <- +CREG: 2,1, B, 2B06 OK 2017-01-05 15:09:39,6, GSM1: Modem is registered to the network 2017-01-05 15:09:39,6, GSM1: Location area code: B, Cell ID: 2B06 2017-01-05 15:09:39,7, GSM1: -> AT+CSQ 2017-01-05 15:09:39,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:40,7, GSM1: <- +CSQ: 12,99 OK 2017-01-05 15:09:40,6, GSM1: Signal Strength Indicator: (12,99) -89 dBm (Workable), Bit Error Rate: not known or not detectable 2017-01-05 15:09:40,6, GSM1: Selecting PDU mode 2017-01-05 15:09:40,7, GSM1: -> AT+CMGF=0 2017-01-05 15:09:40,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:40,7, GSM1: <- OK 2017-01-05 15:09:40,7, GSM1: -> AT+CIMI 2017-01-05 15:09:40,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:41,7, GSM1: <- 615010103851049 OK 2017-01-05 15:09:41,7, GSM1: -> AT+CGSN 2017-01-05 15:09:41,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:41,7, GSM1: <- 359740021706302 OK 2017-01-05 15:09:41,5, GSM1: CGSN: 359740021706302 2017-01-05 15:09:41,5, GSM1: IMSI: 615010103851049 2017-01-05 15:09:41,6, GSM1: Checking if reading of messages is supported 2017-01-05 15:09:41,7, GSM1: -> AT+CPMS? 2017-01-05 15:09:41,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:42,7, GSM1: <- +CPMS: "SM",4,30,"ME",0,0,"SR",0,1 OK 2017-01-05 15:09:42,7, GSM1: -> AT+CMGS=26 2017-01-05 15:09:42,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:42,7, GSM1: <- > 2017-01-05 15:09:42,7, GSM1: -> 0031000B912298302929F00000FF0DD4F29C0E72D7DB65F91B9403. 2017-01-05 15:09:42,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:45,7, GSM1: <- +CMS ERROR: 500 (Unknown error) 2017-01-05 15:09:45,3, GSM1: The modem answer was not OK: +CMS ERROR: 500 (Unknown error) 2017-01-05 15:09:45,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:09:45 3 GSM1 "The modem answer was not OK: +CMS ERROR: 500 (Unknown error)" 2017-01-05 15:09:45,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0) 2017-01-05 15:09:45,3, GSM1: Exec: alarmhandler encountered errors: 2017-01-05 15:09:45,3, GSM1: ! sh: you need to specify whom to kill 2017-01-05 15:09:45,5, GSM1: Waiting 10 sec. before retrying 2017-01-05 15:09:55,6, GSM1: Checking if modem is ready 2017-01-05 15:09:55,7, GSM1: -> AT 2017-01-05 15:09:55,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:09:56,7, GSM1: <- OK 2017-01-05 15:09:59,7, GSM1: -> 0031000B912298302929F00000FF0DD4F29C0E72D7DB65F91B9403. 2017-01-05 15:09:59,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:10:02,7, GSM1: <- +CMS ERROR: 500 (Unknown error) 2017-01-05 15:10:02,3, GSM1: The modem answer was not OK: +CMS ERROR: 500 (Unknown error) 2017-01-05 15:10:02,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:10:02 3 GSM1 "The modem answer was not OK: +CMS ERROR: 500 (Unknown error)" 2017-01-05 15:10:02,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0) 2017-01-05 15:10:26,7, GSM1: -> 0031000B912298302929F00000FF0DD4F29C0E72D7DB65F91B9403. 2017-01-05 15:10:26,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:10:29,7, GSM1: <- +CMS ERROR: 500 (Unknown error) 2017-01-05 15:10:29,3, GSM1: The modem answer was not OK: +CMS ERROR: 500 (Unknown error) 2017-01-05 15:10:29,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:10:29 3 GSM1 "The modem answer was not OK: +CMS ERROR: 500 (Unknown error)"2017-01-05 15:12:18,7, GSM1: <- OK 2017-01-05 15:18:08,6, GSM1: Checking if Modem is registered to the network 2017-01-05 15:18:08,7, GSM1: -> AT+CREG? 2017-01-05 15:18:08,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:18:18,7, GSM1: put_command expected (\+CREG:.*OK)|(ERROR), timeout occurred. 3. 2017-01-05 15:18:18,7, GSM1: <- 2017-01-05 15:18:18,3, GSM1: Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying 2017-01-05 15:18:18,7, GSM1: Running alarmhandler: /www/spool/handler/alarm ALARM 2017-01-05 15:18:18 3 GSM1 "Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying" 2017-01-05 15:18:18,7, GSM1: Done: alarmhandler, execution time 0 sec., status: 0 (0) 2017-01-05 15:18:18,3, GSM1: Exec: alarmhandler encountered errors: 2017-01-05 15:18:18,3, GSM1: ! sh: you need to specify whom to kill 2017-01-05 15:18:19,7, GSM1: -> AT+CSQ 2017-01-05 15:18:19,7, GSM1: Command is sent, waiting for the answer 2017-01-05 15:18:30,7, GSM1: put_command expected (OK)|(ERROR), timeout occurred. 4. 2017-01-05 15:18:30,7, GSM1: <- 2017-01-05 15:18:30,7, GSM1: -> AT+CREG?
juliowilly: Operating system name and version[openwrt Chaos Calmer]: Version of smsd[3.1.15-1]: Smsd installed from: package repository Name and model of a modem : Huawei E182E Interface: USB Hello, i run smstools3 on openwrt chaos calmer and everything seems fine except the fact that i always get this error whith alarm handler Error: Unexpected answer from Modem after +CREG?, waiting 1 sec. before retrying and after that the smstools3 stop running. Please someone can help me to fix that? This is my conf file... # # Description: Main configuration file for the smsd # devices = GSM1 incoming = /www/spool/sms/incoming outgoing = /www/spool/sms/outgoing checked = /www/spool/sms/checked failed = /www/spool/sms/failed sent = /www/spool/sms/sent report = /www/spool/sms/report alarmhandler = /www/spool/handler/alarm receive_before_send = no autosplit = 3 loglevel = 4 [GSM1] init = AT+CPMS="SM","ME","SR" init2 = AT^SYSCFG=13,1,3FFFFFFF,2,4 device = /dev/ttyUSBmodem incoming = yes pin = baudrate = 115200 report = yes eventhandler = /www/spool/handler/event regular_run_interval = 20 regular_run_cmd = AT+CSQ regular_run_cmd = AT+COPS? regular_run_statfile = /tmp/status