matrixworkstation: Operating system name and version: openSUSE 11.4
Version of smsd: 3.1.15
Smsd installed from: Sources
Name and model of a modem / phone: Huawei E173
Interface: USB
Hi!
I'm trying smstools3 and it started working fine but after a while it just stoped.
Here is my config file:
devices = E173
logfile = /var/log/smsd.log
loglevel = 7
[E173]
device = /dev/ttyUSB0
incoming = no
memory_start = 0
And here is the log:
2015-12-09 22:21:50,2, smsd: Smsd v3.1.15 started.
2015-12-09 22:21:50,2, smsd: Running as root:root.
2015-12-09 22:21:50,7, smsd: Running startup_check (shell): /var/spool/sms/incoming/smsd_script.ZCgV5J /tmp/smsd_data.HT2qlf
2015-12-09 22:21:50,7, smsd: Done: startup_check (shell), execution time 0 sec., status: 0 (0)
2015-12-09 22:21:50,4, smsd: File mode creation mask: 077 (0600, rw-------).
2015-12-09 22:21:50,5, smsd: Outgoing file checker has started. PID: 24704.
2015-12-09 22:21:50,7, smsd: All PID's: 24704,24705
2015-12-09 22:21:50,5, E173: Modem handler 0 has started. PID: 24705. Will only send messages.
2015-12-09 22:21:50,6, E173: Checking if modem is ready
2015-12-09 22:21:50,7, E173: -> AT
2015-12-09 22:21:50,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:50,7, E173: <- OK
2015-12-09 22:21:50,6, E173: Pre-initializing modem
2015-12-09 22:21:50,7, E173: -> ATE0+CMEE=1;+CREG=2
2015-12-09 22:21:50,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:51,7, E173: <- OK
2015-12-09 22:21:51,6, E173: Checking if modem needs PIN
2015-12-09 22:21:51,7, E173: -> AT+CPIN?
2015-12-09 22:21:51,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:51,7, E173: <- +CPIN: READY OK
2015-12-09 22:21:51,7, E173: -> AT+CSQ
2015-12-09 22:21:51,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:52,7, E173: <- +CSQ: 11,0 OK
2015-12-09 22:21:52,6, E173: Signal Strength Indicator: (11,0) -91 dBm (Workable), Bit Error Rate: less than 0.2 %
2015-12-09 22:21:52,6, E173: Checking if Modem is registered to the network
2015-12-09 22:21:52,7, E173: -> AT+CREG?
2015-12-09 22:21:52,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:52,7, E173: <- +CREG: 2,1,"755C","2B1E" OK
2015-12-09 22:21:52,6, E173: Modem is registered to the network
2015-12-09 22:21:52,6, E173: Location area code: 755C, Cell ID: 2B1E
2015-12-09 22:21:52,7, E173: -> AT+CSQ
2015-12-09 22:21:52,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:53,7, E173: <- +CSQ: 11,0 OK
2015-12-09 22:21:53,6, E173: Signal Strength Indicator: (11,0) -91 dBm (Workable), Bit Error Rate: less than 0.2 %
2015-12-09 22:21:53,6, E173: Selecting PDU mode
2015-12-09 22:21:53,7, E173: -> AT+CMGF=0
2015-12-09 22:21:53,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:53,7, E173: <- OK
2015-12-09 22:21:53,7, E173: -> AT+CIMI
2015-12-09 22:21:53,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:54,7, E173: <- 724054203997068 OK
2015-12-09 22:21:54,7, E173: -> AT+CGSN
2015-12-09 22:21:54,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:54,7, E173: <- 863133010845324 OK
2015-12-09 22:21:54,5, E173: CGSN: 863133010845324
2015-12-09 22:21:54,5, E173: IMSI: 724054203997068
2015-12-09 22:21:54,5, E173: Waiting for messages to send...
2015-12-09 22:21:54,6, E173: I have to send 1 short message for /var/spool/sms/checked/SMS_send_88aIj8
2015-12-09 22:21:54,6, E173: Sending SMS from me@domain.com to XXXXXXXXXX
2015-12-09 22:21:54,6, E173: Checking if modem is ready
2015-12-09 22:21:54,7, E173: -> AT
2015-12-09 22:21:54,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:55,7, E173: <- OK
2015-12-09 22:21:55,6, E173: Pre-initializing modem
2015-12-09 22:21:55,7, E173: -> ATE0+CMEE=1;+CREG=2
2015-12-09 22:21:55,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:55,7, E173: <- OK
2015-12-09 22:21:55,7, E173: -> AT+CSQ
2015-12-09 22:21:55,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:56,7, E173: <- +CSQ: 11,0 OK
2015-12-09 22:21:56,6, E173: Signal Strength Indicator: (11,0) -91 dBm (Workable), Bit Error Rate: less than 0.2 %
2015-12-09 22:21:56,6, E173: Checking if Modem is registered to the network
2015-12-09 22:21:56,7, E173: -> AT+CREG?
2015-12-09 22:21:56,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:56,7, E173: <- +CREG: 2,1,"755C","2B1E" OK
2015-12-09 22:21:56,6, E173: Modem is registered to the network
2015-12-09 22:21:56,6, E173: Selecting PDU mode
2015-12-09 22:21:56,7, E173: -> AT+CMGF=0
2015-12-09 22:21:56,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:57,7, E173: <- OK
2015-12-09 22:21:57,7, E173: -> AT+CMGS=82
2015-12-09 22:21:57,7, E173: Command is sent, waiting for the answer
2015-12-09 22:21:57,7, E173: <- >
2015-12-09 22:21:57,7, E173: -> <hidden data>^Z
2015-12-09 22:21:57,7, E173: Command is sent, waiting for the answer
2015-12-09 22:22:28,7, E173: <- +CMS ERROR: 500 (Unknown error)
2015-12-09 22:22:28,3, E173: The modem answer was not OK: +CMS ERROR: 500 (Unknown error)
2015-12-09 22:22:28,5, E173: Waiting 10 sec. before retrying
Thanks.
|