mrbob909: Hi, I'm sorry about the confusion, I'm using 3.1.2. I'm just using the package, someone else maintains the server and he installed it for me. But you were right there were multiple smsd daemons running. They were all killed and the daemon was properly started. First tests showed a good results so far. Thanks
mrbob909: CSQ 12 means that signal is not very strong. A value near to 20 or more is better. 99 means that Bit Error Rate is not measurable. Next version will explain values in the log. I have to check your log more, but one question now: did you restart smsd after changing smsd.conf? Hi, Yes, I did restart the daemon each time I made a config change. The CSQ value is stable around 17,99 so that should be OK. It seems like smsd is just impatient and it sends too many commands too fast for my modem to handle. It should wait longer between each command because my sms modem just can't keep up.
mrbob909: I have run the AT+CSQ command a few times with my PC connected to the SMS modem. It returned values between 14,99 and 17,99.
mrbob909: Thanks for the quick reply. This is the config file : devices = SiemensMC35i outgoing = /var/spool/sms/outgoing checked = /var/spool/sms/checked failed = /var/spool/sms/failed #incoming = /var/spool/sms/incoming #report = /var/spool/sms/report #sent = /var/spool/sms/sent logfile = /var/log/smsd.log loglevel = 7 [SiemensMC35i] init = AT+CPMS="SM" device = /dev/ttyS0 incoming = no outgoing = yes smsc = 0475161616 baudrate = 115200 rtscts = yes read_timeout = 60 init2 = AT+CSQ I use 3.1.5beta8. No incoming SMS messages are allowed. I have tried to increase the read_timeout to 60 seconds without improvement. Here is a new piece of log. 2009-05-18 13:18:38,6, SiemensMC35i: Used memory is 0 of 30 2009-05-18 13:18:38,6, SiemensMC35i: No SMS received 2009-05-18 13:18:41,6, smsd: Moved file /var/spool/sms/outgoing/send_cnbDum to /var/spool/sms/checked 2009-05-18 13:18:42,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_cnbDum 2009-05-18 13:18:42,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 13:18:42,6, SiemensMC35i: Checking if modem is ready 2009-05-18 13:18:42,7, SiemensMC35i: -> AT 2009-05-18 13:18:42,6, smsd: Moved file /var/spool/sms/outgoing/send_nVCHuJ to /var/spool/sms/checked 2009-05-18 13:18:42,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:42,7, SiemensMC35i: <- OK 2009-05-18 13:18:42,6, SiemensMC35i: Pre-initializing modem 2009-05-18 13:18:42,7, SiemensMC35i: -> ATE0+CMEE=1 2009-05-18 13:18:42,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:43,7, SiemensMC35i: <- OK 2009-05-18 13:18:43,6, SiemensMC35i: Initializing modem 2009-05-18 13:18:43,7, SiemensMC35i: -> AT+CPMS="SM" 2009-05-18 13:18:43,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:43,7, SiemensMC35i: <- +CPMS: 0,30,2,55,2,55 OK 2009-05-18 13:18:43,7, SiemensMC35i: -> AT+CSQ 2009-05-18 13:18:43,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:43,6, smsd: Moved file /var/spool/sms/outgoing/send_labhSo to /var/spool/sms/checked 2009-05-18 13:18:43,7, SiemensMC35i: <- +CSQ: 12,99 OK 2009-05-18 13:18:43,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 13:18:43,7, SiemensMC35i: -> AT+CREG? 2009-05-18 13:18:43,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:43,7, SiemensMC35i: <- +CREG: 0,1 OK 2009-05-18 13:18:43,6, SiemensMC35i: Modem is registered to the network 2009-05-18 13:18:43,6, SiemensMC35i: Selecting PDU mode 2009-05-18 13:18:43,7, SiemensMC35i: -> AT+CMGF=0 2009-05-18 13:18:43,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:44,7, SiemensMC35i: <- OK 2009-05-18 13:18:44,6, SiemensMC35i: Changing SMSC 2009-05-18 13:18:44,7, SiemensMC35i: -> AT+CSCA="+xxxxxxxxxx" 2009-05-18 13:18:44,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:44,6, smsd: Moved file /var/spool/sms/outgoing/send_xAprrR to /var/spool/sms/checked 2009-05-18 13:18:44,7, SiemensMC35i: <- OK 2009-05-18 13:18:44,7, SiemensMC35i: -> AT+CIMI 2009-05-18 13:18:44,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:44,7, SiemensMC35i: <- 206011901843280 OK 2009-05-18 13:18:44,6, SiemensMC35i: IMSI: 206011901843280 2009-05-18 13:18:44,7, SiemensMC35i: -> AT+CMGS=19 2009-05-18 13:18:44,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:45,7, SiemensMC35i: <- > 2009-05-18 13:18:45,7, SiemensMC35i: -> ( PDU REMOVED ) 2009-05-18 13:18:45,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:45,6, smsd: Moved file /var/spool/sms/outgoing/send_AVYGLv to /var/spool/sms/checked 2009-05-18 13:18:46,6, smsd: Moved file /var/spool/sms/outgoing/send_YzQXPC to /var/spool/sms/checked 2009-05-18 13:18:47,6, smsd: Moved file /var/spool/sms/outgoing/send_CgpOej to /var/spool/sms/checked 2009-05-18 13:18:47,7, SiemensMC35i: <- +CMGS: 29 OK 2009-05-18 13:18:47,5, SiemensMC35i: SMS sent, Message_id: 29, To: xxxxxxxxxx, sending time 5 sec. 2009-05-18 13:18:47,6, SiemensMC35i: Deleted file /var/spool/sms/checked/send_cnbDum 2009-05-18 13:18:48,6, smsd: Moved file /var/spool/sms/outgoing/send_mNfkLQ to /var/spool/sms/checked 2009-05-18 13:18:48,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_nVCHuJ 2009-05-18 13:18:48,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 13:18:48,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 13:18:48,7, SiemensMC35i: -> AT+CREG? 2009-05-18 13:18:48,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:48,7, SiemensMC35i: <- +CREG: 0,1 OK 2009-05-18 13:18:48,6, SiemensMC35i: Modem is registered to the network 2009-05-18 13:18:48,7, SiemensMC35i: -> AT+CMGS=19 2009-05-18 13:18:48,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:49,7, SiemensMC35i: <- > 2009-05-18 13:18:49,7, SiemensMC35i: -> ( PDU REMOVED ) 2009-05-18 13:18:49,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:49,6, smsd: Moved file /var/spool/sms/outgoing/send_IRqNjU to /var/spool/sms/checked 2009-05-18 13:18:49,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_labhSo 2009-05-18 13:18:49,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 13:18:49,6, SiemensMC35i: Checking if modem is ready 2009-05-18 13:18:49,7, SiemensMC35i: -> AT 2009-05-18 13:18:49,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:49,7, SiemensMC35i: <- OK 2009-05-18 13:18:49,5, SiemensMC35i: SMS sent, Message_id: , To: xxxxxxxxxx, sending time 1 sec. 2009-05-18 13:18:49,6, SiemensMC35i: Deleted file /var/spool/sms/checked/send_nVCHuJ 2009-05-18 13:18:50,6, smsd: Moved file /var/spool/sms/outgoing/send_xgDlHh to /var/spool/sms/checked 2009-05-18 13:18:50,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_xAprrR 2009-05-18 13:18:50,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 13:18:50,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 13:18:50,7, SiemensMC35i: -> AT+CREG? 2009-05-18 13:18:50,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:50,7, SiemensMC35i: <- +CREG: 0,1 OK 2009-05-18 13:18:50,6, SiemensMC35i: Modem is registered to the network 2009-05-18 13:18:50,7, SiemensMC35i: -> AT+CMGS=19 2009-05-18 13:18:50,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:51,7, SiemensMC35i: <- > 2009-05-18 13:18:51,7, SiemensMC35i: -> ( PDU REMOVED ) 2009-05-18 13:18:51,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:51,6, smsd: Moved file /var/spool/sms/outgoing/send_QrLgOi to /var/spool/sms/checked 2009-05-18 13:18:54,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:18:54,7, SiemensMC35i: <- 2009-05-18 13:18:54,7, SiemensMC35i: -> 2009-05-18 13:18:54,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:54,7, SiemensMC35i: <- +CMGS: 31 OK 2009-05-18 13:18:54,5, SiemensMC35i: SMS sent, Message_id: 31, To: xxxxxxxxxx, sending time 4 sec. 2009-05-18 13:18:54,6, SiemensMC35i: Deleted file /var/spool/sms/checked/send_xAprrR 2009-05-18 13:18:55,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_AVYGLv 2009-05-18 13:18:55,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 13:18:55,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 13:18:55,7, SiemensMC35i: -> AT+CREG? 2009-05-18 13:18:55,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:18:59,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:18:59,7, SiemensMC35i: <- +CREG: 0,1 2009-05-18 13:18:59,7, SiemensMC35i: -> AT 2009-05-18 13:18:59,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:04,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:19:04,7, SiemensMC35i: <- 2009-05-18 13:19:04,7, SiemensMC35i: -> 2009-05-18 13:19:04,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:09,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:19:09,7, SiemensMC35i: <- 2009-05-18 13:19:09,7, SiemensMC35i: -> AT 2009-05-18 13:19:09,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:14,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:19:14,7, SiemensMC35i: <- 2009-05-18 13:19:14,7, SiemensMC35i: -> 2009-05-18 13:19:14,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:19,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:19:19,7, SiemensMC35i: <- 2009-05-18 13:19:19,7, SiemensMC35i: -> AT 2009-05-18 13:19:19,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:24,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:19:24,7, SiemensMC35i: <- 2009-05-18 13:19:24,7, SiemensMC35i: -> 2009-05-18 13:19:24,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:29,7, SiemensMC35i: put_command expected (OK)|(ERROR), timeout occurred. 2009-05-18 13:19:29,7, SiemensMC35i: <- 2009-05-18 13:19:29,7, SiemensMC35i: -> AT 2009-05-18 13:19:29,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:29,7, SiemensMC35i: <- OK 2009-05-18 13:19:29,6, SiemensMC35i: Pre-initializing modem 2009-05-18 13:19:29,7, SiemensMC35i: -> ATE0+CMEE=1 2009-05-18 13:19:29,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:30,7, SiemensMC35i: <- OK 2009-05-18 13:19:30,6, SiemensMC35i: Initializing modem 2009-05-18 13:19:30,7, SiemensMC35i: -> AT+CPMS="SM" 2009-05-18 13:19:30,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:30,7, SiemensMC35i: <- +CPMS: 0,30,2,55,2,55 OK 2009-05-18 13:19:30,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 13:19:30,7, SiemensMC35i: -> AT+CREG? 2009-05-18 13:19:30,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 13:19:30,7, SiemensMC35i: <- +CREG: 0,1 OK 2009-05-18 13:19:30,6, SiemensMC35i: Modem is registered to the network 2009-05-18 13:19:30,6, SiemensMC35i: Selecting PDU mode 2009-05-18 13:19:30,7, SiemensMC35i: -> AT+CMGF=0 2009-05-18 13:19:30,7, SiemensMC35i: Command is sent, waiting for the answer ... What should indicate the singnal quality in the log. Also when I tail the log file it never seems to wait for 60 seconds for anything.
mrbob909: Hi, About 1 out of 4 SMS messages I try to send get lost in the process. This seems to be caused by timeouts occurring. “put_command expected (>)|(ERROR), timeout occurred” I use a rather slow Siemens MC35i so I’ve tried to set the read_timeout to 20 seconds but even that didn’t seem to solve the problem. I've also tried experimenting with different baud rates but that seemed to make it even worse. What could be causing this issue ? This is a piece of the log file with the timeout : … 2009-05-18 11:41:01,6, SiemensMC35i: Deleted file /var/spool/sms/checked/send_fBQupr 2009-05-18 11:41:02,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_cuVXbA 2009-05-18 11:41:02,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 11:41:02,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 11:41:02,7, SiemensMC35i: -> AT+CREG? 2009-05-18 11:41:02,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:02,7, SiemensMC35i: <- +CREG: 0,1 OK 2009-05-18 11:41:02,6, SiemensMC35i: Modem is registered to the network 2009-05-18 11:41:02,7, SiemensMC35i: -> AT+CMGS=19 2009-05-18 11:41:02,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:03,7, SiemensMC35i: <- > 2009-05-18 11:41:03,7, SiemensMC35i: -> ( PDU REMOVED ) 2009-05-18 11:41:03,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:06,7, SiemensMC35i: <- +CMGS: 15 OK 2009-05-18 11:41:06,5, SiemensMC35i: SMS sent, Message_id: 15, To: xxxxxxxxxx, sending time 4 sec. 2009-05-18 11:41:06,6, SiemensMC35i: Deleted file /var/spool/sms/checked/send_cuVXbA 2009-05-18 11:41:06,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_Zfmxwi 2009-05-18 11:41:06,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 11:41:06,6, SiemensMC35i: Checking if modem is ready 2009-05-18 11:41:06,7, SiemensMC35i: -> AT 2009-05-18 11:41:06,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:07,7, SiemensMC35i: <- OK 2009-05-18 11:41:07,6, SiemensMC35i: Pre-initializing modem 2009-05-18 11:41:07,7, SiemensMC35i: -> ATE0+CMEE=1 2009-05-18 11:41:07,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:07,7, SiemensMC35i: <- OK 2009-05-18 11:41:07,6, SiemensMC35i: Initializing modem 2009-05-18 11:41:07,7, SiemensMC35i: -> AT+CPMS="SM" 2009-05-18 11:41:07,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:07,7, SiemensMC35i: <- +CPMS: 0,30,2,55,2,55 OK 2009-05-18 11:41:07,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 11:41:07,7, SiemensMC35i: -> AT+CREG? 2009-05-18 11:41:07,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:08,6, SiemensMC35i: I have to send 1 short message for /var/spool/sms/checked/send_sGIFSE 2009-05-18 11:41:08,6, SiemensMC35i: Sending SMS from to xxxxxxxxxx 2009-05-18 11:41:08,6, SiemensMC35i: Checking if Modem is registered to the network 2009-05-18 11:41:08,7, SiemensMC35i: -> AT+CREG? 2009-05-18 11:41:08,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:08,7, SiemensMC35i: <- +CREG: 0,1 OK +CREG: 0,1 OK 2009-05-18 11:41:08,6, SiemensMC35i: Modem is registered to the network 2009-05-18 11:41:08,6, SiemensMC35i: Selecting PDU mode 2009-05-18 11:41:08,7, SiemensMC35i: -> AT+CMGF=0 2009-05-18 11:41:08,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:08,7, SiemensMC35i: <- OK 2009-05-18 11:41:08,6, SiemensMC35i: Changing SMSC 2009-05-18 11:41:08,7, SiemensMC35i: -> AT+CSCA="+xxxxxxxxxx" 2009-05-18 11:41:08,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:08,7, SiemensMC35i: <- OK 2009-05-18 11:41:08,7, SiemensMC35i: -> AT+CMGS=19 2009-05-18 11:41:08,7, SiemensMC35i: Command is sent, waiting for the answer 2009-05-18 11:41:13,7, SiemensMC35i: put_command expected (>)|(ERROR), timeout occurred. 2009-05-18 11:41:13,7, SiemensMC35i: <- 2009-05-18 11:41:13,7, SiemensMC35i: -> ( PDU REMOVED ) 2009-05-18 11:41:13,7, SiemensMC35i: Command is sent, waiting for the answer….