SMS Server Tools 3
This site is hosted by Kekekasvi.com
 Menu
Basic information:
Additional information:
Support:
Get SMS Server Tools 3:
Additional Options

 Sponsored links

 Search
Custom Search

 Visitor locations
 
 SMS Server Tools 3 Community
Welcome, Guest. Please login or register. Wed Apr 24, 2024 17:48
SMSTools3 Community » Help and support Bottom

[outdated] Siemens ES75

  This topic is locked

Page:  1

Author Post
Member
Registered:
Mar 2010
Location: Czech Republic
Operating system name and version: Win XP
Version of smsd: 3.1.6
Smsd installed from: sources
Name and model of a modem / phone: Siemens ES75
Interface: serial

Hi, please how to configure siemens es75?

my config file

devices = GSM1
outgoing = /var/spool/sms/outgoing
checked = /var/spool/sms/checked
failed = /var/spool/sms/failed
incoming = /var/spool/sms/incoming
report = /var/spool/sms/report
sent = /var/spool/sms/sent
logfile = /var/log/smsd.log
loglevel = 7
stats = /var/spool/sms/stats
keep_filename = no
date_filename = 1
os_cygwin = yes
hangup_incoming_call = yes
smart_logging = yes

[GSM1]
init =
device = /dev/com5
incoming = yes
memory_start = 1
# pin =
baudrate = 115200
phonecalls = no
smsc = 420603052000


Thank you for Helping!

Administrator
Registered:
May 2009
Location: Jyväskylä, Finland
Assuming that you cannot receive any messages, even when there surely is at least one message in the modem, try this definition:

init = AT+CPMS="ME","ME","ME"

If you have an unexpected input detected in the log, try this:
init2 = AT+CNMI=1,1,0,2

If you still do not get this device working, show a piece of a log here, or describe what the problem is.

Member
Registered:
Mar 2010
Location: Czech Republic
Topic owner
Thank's but not working.

[GSM1]
#init = AT+CPMS="ME","ME","ME"
init = AT+CNMI=1,1,0,2
device = /dev/com5
incoming = yes
memory_start = 1
# pin =
baudrate = 115200
phonecalls = no
#smsc = 420603052000


Log



Administrator
Registered:
May 2009
Location: Jyväskylä, Finland
For some reason your device does not answer when CPMS? is asked. Perhaps this is because preferred message storage was not set.

Test this issue using a communication mode of smsd:

Stop the smsd if it's running.
Start it with smsd -C GSM1. Follow the instructions on screen.

Type ATE1 (and Enter) to set echo on.

Use the following commands:

AT+CPMS=? to get a list of storages.

AT+CPMS="SM" to select SIM.

AT+CPMS? to see if there are messages.

AT+CPMS="ME" to select mobile equipment.

AT+CPMS? to see if there are messages.

Show the result of a communication here.

  This topic is locked

Page:  1

SMSTools3 Community » Help and support Top

 
Time in this board is UTC.  