#1 Fri Aug 05, 2011 11:31, 162 months ago.
|
Member
Registered: Sep 2010
Location: Brazil
|
Operating system name and version: Windows 7 + CYGWIN Version of smsd: 3.1.12 Smsd installed from: sources Name and model of a modem / phone: Teltonika 3G USB modem UM5100 Interface: USB
sometimes it works fine, but when the log shows the below msg, right after activation, it will not receive any SMS. ... <- +CPMS: "ME",0,0,"ME",0,0,"SM",3,20 OK GSM1: Used memory is 0 of 0 ... Not sure how to fix this, I had rebooted the whole thing to no avail. thanks! RR
|
|
#2 Fri Aug 05, 2011 11:41, 162 months ago.
|
Administrator
Registered: May 2009
Location: Jyväskylä, Finland
|
Do you use any init string? If not, init = AT+CPMS="SM","SM","SM" could help.
|
|
#3 Fri Aug 05, 2011 11:44, 162 months ago.
|
Member
Registered: Sep 2010
Location: Brazil
Topic owner
|
follow up: I rebooted the PC, run teltonika's modem utility (comes with the modem to send/receive msg), sent a sms to the modem, saw it on the UI, stopped/exited the teltonika sw and run cygwin/smstools3. Now it works. Any comments? thanks RR
|
|
#4 Fri Aug 05, 2011 12:02, 162 months ago.
|
Administrator
Registered: May 2009
Location: Jyväskylä, Finland
|
It looks like Teltonika's software initialized the modem to use SM memory. The init string should help. Reset the modem and try it without running Teltonika's software first.
|
|
#5 Fri Aug 05, 2011 13:42, 162 months ago.
|
Member
Registered: Sep 2010
Location: Brazil
Topic owner
|
Keke, Teltonika's software is needed to create the virtual COM port. I run it and then quit. Is there any other way to create the com port? Thanks!
|
|
#6 Fri Aug 05, 2011 13:48, 162 months ago.
|
Administrator
Registered: May 2009
Location: Jyväskylä, Finland
|
If Teltonika's drivers do not create the port without running the utility, you just have to run it...
Have you tried the init string? It still should work.
|
|
#7 Sat Aug 06, 2011 02:17, 162 months ago.
|
Member
Registered: Sep 2010
Location: Brazil
Topic owner
|
Keke, I am using the init string you recommended, so far so good, receiving/xmitting is perfect. I am just intrigued by this error msg, please let me know if it is expected:
Trying to get stored message 20 2011-08-05 23:11:54,7, GSM13: -> AT+CMGR=20 2011-08-05 23:11:54,7, GSM13: Command is sent, waiting for the answer 2011-08-05 23:11:55,7, GSM13: <- +CMS ERROR: 321 (Invalid memory index) 2011-08-05 23:11:55,6, GSM13: No SMS received (reading interrupted) 2011-08-05 23:12:05,6, GSM13: Checking device for incoming SMS
BTW, what to do about the com port that changes depending on the USB port you use? I created one modem section for each port, not sure there are more elegant solutions for this.
Thanks! RR
|
|
#8 Wed Aug 24, 2011 16:06, 162 months ago.
|
Administrator
Registered: May 2009
Location: Jyväskylä, Finland
|
If you still have errors while trying to receive messages, try a modem setting memory_start = 0. If it does not help, show your current setup and piece of a log which shows how smsd is trying to read first messages.
For changes of COM port I do not have any good hints currently.
|