Welcome, Guest. The forum is currently read-only, but will open soon. Thu Nov 21, 2024 17:59
SMSTools3 Community » Help and support Bottom

Missed calls cant be deleted / AT+CPBW=1 error

Login and Post Reply

Page:  1

Author Post
Member
Registered:
Oct 2018
Location: Germany
Phonebook entries in MC storage cant be deleted in some of my modems.



smstools logs:



Every time smstools gets restarted I get same events again. Like in this post it would be possible do accept CME ERROR when trying to deleted an entry. But that would not solve our problem. I think events would be fired repeated every time PB gets read.

Docs about m39i says: "In the”MC”, ”RC” and ”LD” phonebooks, automatic deletion of the entries stored in ME will be performed if the SIM card is changed. If the same SIM is removed and reinserted, no automatic deletion
is performed. "


Is there any possibility to avoid these duplicates? Maybe read a timestamp of the missed call?

Or maybe only fire event when RING comes in? This would be a great solution to avoid PB usage and receive incoming call events in real time.

Thanks in advance.


Operating system name and version: Ubuntu 20.04.2 LTS
Version of smsd: 3.1.21
Smsd installed from: sources
Name and model of a modem / phone: Siemens MC39i
Interface: Exar


« Last edit by cl77 on Tue Aug 31, 2021 14:16, 39 months ago. »
Member
Registered:
Oct 2018
Location: Germany
Topic owner
Darn. phonecalls_purge=yes did it....